Ambient Scenting and Odor Control System Air Flow Sensor


Ambient scenting and odor control systems normally emit odor, whether or not there is air flow in the environment, at specified time intervals. When used with this sensor, it provides a balanced working environment by operating the system in case of air flow in the environment. 

In short, the Air Flow Sensor is a product made for the AC voltage switching of the ambient scent system.

  • Working voltage: 90-240VAC
  • Maximum current: 1A
  • Short circuit protected
  • Open circuit protected
  • Working Temperature: 0 ° C ~ 60 ° C
  • Suitable for industrial standards

Basic Working Algorithm:

  • When the air flow sensor is plugged in, firstly, the resistance on the sensor heats up for about 1-1.5 minutes and its temperature reaches an average of 60 degrees.
  • If there is air flow (circulation) in the environment, the resistance temperature drops, if it drops below the specified temperature, it gives AC output and operates the ambient odor system.
  • If the ambient temperature rises above the specified temperature, the AC output turns off again.